Rapid waste-valve closure launches a pressure wave. The ideal Joukowsky head rise is corrected for closure time and an illustrative air-chamber damping factor.
tc = 0.035 + 0.035√(mv / 0.18 kg) s
ΔH = (a Δv / g) · Cc · Ca · 0.68
Delivery volume follows a cycle energy balance; the pressure pulse gates the delivery check valve.
η = HdeliveryQout / (HdriveQin)
Textbook constants: ρ = 998 kg/m³, g = 9.81 m/s², a = 950 m/s. Illustrative values: operating settings, valve coupling and transient traces; assembly geometry is schematic, not to scale.
Constant density and wave speed; Gaussian pulse; calibrated lumped cycle timing. This is an educational transient approximation, not CFD or a pump sizing tool.
Illustrative design, not affiliated with any real institution or manufacturer.