THERMAL ATLAS
ENERGY SYSTEMS / 01SEED 482731
03 / DRIVE-CYCLE EXPERIMENT

Heat has a memory.

Repeated current pulses create a delayed thermal response. The lower trace is the electrical demand; the upper trace is the module's temperature.

Thermal response · temperature (°C)

Load programme · current (A)

Peak temperature—°C · full cycle
Energy input—Wh · integrated I²R
Peak delay—s · after cycle start
Trial spread—°C · 3 noisy sensors
Deterministic noise · ±0.25 °C
Independent check — analytic first-pulse response.
The science — equations and simplifications

The model treats the battery module as one uniform thermal node. Electrical heating is ohmic; heat leaves through an effective module-to-coolant conductance and thermal radiation.

C · dT/dt = I²R − UA(T − Tₐ) − εσAₛ[(T+273.15)⁴ − (Tₐ+273.15)⁴]

C = m cₚ is thermal capacitance (J K⁻¹); R is resistance (Ω); UA is effective conductance (W K⁻¹); ε is emissivity; σ is the Stefan–Boltzmann constant. Current and resistance are held constant within each time step.

Simplifications: a single lumped temperature, no cell-to-cell gradients, no reversible/entropic heat, no temperature-dependent resistance, no coolant warm-up along the channel, and no phase change. The flow-to-UA relation in the design map is an illustrative power law, not a manufacturer correlation.

Readouts are illustrative values from a textbook-style lumped model, not validated pack predictions. The model is for learning and comparison, not battery safety or engineering sign-off.

Illustrative design, not affiliated with any real institution or manufacturer.

THERMAL ATLAS · FAMILY STUDY 01Scientific model / not a product specification
Made with 🤖 ChatGPT