From stress to colour
The plate is modelled as an infinite, homogeneous, isotropic, linearly elastic sheet with a circular hole under remote uniaxial tension. The exact Kirsch solution gives the in-plane stress field outside the hole.
σrr = ½σ∞(1 − a²/r²) + ½σ∞(1 − 4a²/r² + 3a⁴/r⁴) cos 2θ
σθθ = ½σ∞(1 + a²/r²) − ½σ∞(1 + 3a⁴/r⁴) cos 2θ
τrθ = −½σ∞(1 + 2a²/r² − 3a⁴/r⁴) sin 2θ
Here a is the hole radius, r and θ locate a point, and σ∞ is the far-field tensile stress. The polar stresses are transformed into Cartesian components before the principal stress difference Δσ and principal direction φ are found.
Photoelastic law
N = C t Δσ / λ · I/I₀ = sin²(πN) sin²[2(φ − α)]
C is the stress-optic coefficient, t is plate thickness, λ is wavelength, and α is the first polarizer angle. The analyser is fixed at 90° to the first polarizer. The displayed white-light colours are an illustrative three-wavelength RGB sampling (650, 550 and 450 nm), not a full spectral or camera model.
What is simplified
- The Kirsch solution assumes an infinite plate; the drawn specimen has finite edges only for visual context.
- The material is homogeneous, isotropic, linear-elastic and in plane stress. Residual stress, plasticity, viscoelasticity and thickness variation are omitted.
- The optical coefficient is illustrative. Real photoelastic constants depend on material, wavelength, temperature and processing.
- The 55 MPa tensile limit is an illustrative threshold, not a certified material property. Crack marks indicate loss of model validity; crack growth is not simulated.
- The field is an analytical equilibrium solution, not a time-stepped fracture or finite-element calculation.