A low energy number is not enough: the membrane still needs driving pressure and a sensible flux.
Sweep pressure and recovery to find low-energy operating regions that retain useful membrane driving pressure. The values are calculated from the shared family model and update as you change the operating conditions.
The map evaluates a grid of feed pressure and recovery values. Cells are marked feasible when net driving pressure is at least 5 bar and the calculated permeate flux lies between 5 and 25 LMH. These are illustrative screening bounds, not a membrane-vendor guarantee.
Qp = Qf × R · Qb = Qf − Qp · salt balance: Qf Sf = Qp Sp + Qb Sb.
NaCl-equivalent osmotic pressure: π ≈ 0.846 S (T/298.15) × 1.08 bar, with S in g/L and T in kelvin. Net driving pressure is feed pressure less half the pressure drop, mean osmotic pressure and an approximately 1 bar permeate pressure.
Pump hydraulic input uses Q × P × 0.02778 kW for Q in m³/h and P in bar. The pressure exchanger returns Qb × Pbrine × ηPX × 0.02778. Specific energy is net electrical kW divided by permeate m³/h.
Assumptions: steady state; ideal salt accounting; constant pump and exchanger efficiencies; no detailed membrane transport, staging, leakage, scaling or thermal losses. Illustrative screening model, not plant design software.