Textbook / illustrative model. The clutch uses alternating annular plates separated by a magnetorheological (MR) fluid. An energised coil creates a magnetic field that increases the fluid's field-dependent yield stress. Relative rotation adds a viscous shear contribution.
B = min(Bsat, μ₀ N I / (2g + ℓcore,eq)) τ(r) = τy(B) + η Δω r / g; τy = τsat [1 − exp(−(B/B₀)^1.6)] T = n · 2π ∫ᵣᵢʳᵒ τ(r) r² dr = n[2πτy(rₒ³−rᵢ³)/3 + πηΔω(rₒ⁴−rᵢ⁴)/(2g)] Pslip = T ΔωAssumptions: uniform magnetic flux across the active gaps; constant viscosity; a Bingham-like yield-plus-viscous stress law; identical parallel gaps; no leakage, edge effects, temperature rise, magnetic hysteresis, plate deformation, or transient field response. The equivalent magnetic path and rheology constants are illustrative, not a manufacturer specification. The numerical check independently integrates local shear-stress moment using midpoint quadrature.
Readouts are SI-based model outputs. The cross-section and field lines are schematic, not to geometric scale.
Illustrative design, not affiliated with any real institution or manufacturer.