Damper cross-sectionTextbook schematic
Coil field · annular flow · pistonFIELD ACTIVE
Force–velocity response
Field offCurrent field1.2 T
Field-strength sweepAt current speed
τᵧ(B) = τsat B² / (B² + Bsat²); temperature-dependent viscosity is μ(T) = μref exp[−β(T − Tref)]. The resisting force combines a regularised yield term and laminar slit-flow term: F = −Ap [2Lτᵧ/g · tanh(v/vs) + 12μLApv/(wg³)]. Dissipated power is P = |Fv|.