THERMAL ATLAS
ENERGY SYSTEMS / 01SEED 482731
02 / COOLING DESIGN MAP

Find the cooling window.

Choose a point on the operating map. Flow sets an illustrative effective UA; current sets the heat load.

Steady-state temperature envelope

Click anywhere in the map to select flow and current.

Equilibrium °C
CoolerNominalWarmHotter
Predicted equilibrium—°C · nonlinear balance
Heat generation—W · I²R
Effective UA—W/K · flow law
Thermal time—s · C / UA
Independent check — analytic convection solution.
The science — equations and simplifications

The model treats the battery module as one uniform thermal node. Electrical heating is ohmic; heat leaves through an effective module-to-coolant conductance and thermal radiation.

C · dT/dt = I²R − UA(T − Tₐ) − εσAₛ[(T+273.15)⁴ − (Tₐ+273.15)⁴]

C = m cₚ is thermal capacitance (J K⁻¹); R is resistance (Ω); UA is effective conductance (W K⁻¹); ε is emissivity; σ is the Stefan–Boltzmann constant. Current and resistance are held constant within each time step.

Simplifications: a single lumped temperature, no cell-to-cell gradients, no reversible/entropic heat, no temperature-dependent resistance, no coolant warm-up along the channel, and no phase change. The flow-to-UA relation in the design map is an illustrative power law, not a manufacturer correlation.

Readouts are illustrative values from a textbook-style lumped model, not validated pack predictions. The model is for learning and comparison, not battery safety or engineering sign-off.

Illustrative design, not affiliated with any real institution or manufacturer.

THERMAL ATLAS · FAMILY STUDY 01Scientific model / not a product specification