A current-carrying coil turns in a magnetic field. Its fibre resists the twist; damping limits the motion.
IDEAL MAGNETIC GAP · TEXTBOOK RELATION
B ≈ μ₀ Nₘ Iₘ / g
μ₀ ≈ 4π × 10⁻⁷ H/m (textbook approximation); Nₘ = 1,500 turns and g = 10 mm (illustrative). Leakage and iron reluctance are omitted.
ROTATIONAL MOTION · TEXTBOOK FORM
J θ̈ + c θ̇ + κ θ = N B A I
Inertia × angular acceleration + damping + fibre restoring torque = electromagnetic torque.
COIL CIRCUIT · QUASI-STATIC
I = (V − N B A θ̇) / R
The back-emf term gives electromagnetic damping; coil inductance is neglected. Signal coil: N = 420 turns, A = 1.35 cm², R = 24 kΩ, J = 1.2 × 10⁻⁷ kg·m² and siphon lever ℓ = 65 mm (all illustrative).
NATURAL FREQUENCY & DAMPING
ωₙ = √(κ/J) · ζ = (c + G²/R) / (2√(Jκ))
G = N B A. The G²/R term is electromagnetic damping from coil back-emf.
TEXTBOOK HISTORYWilliam Thomson patented the siphon recorder in 1867. Early versions used electromagnets; later versions also used permanent magnets. A suspended coil moved the glass siphon while electrostatic charge propelled ink onto a grounded, moving paper strip.
MODEL SIMPLIFICATIONSOne rotational degree of freedom; linear fibre; uniform magnetic field; lumped inertia; quasi-static coil current. Cable dispersion, ink-drop breakup, electrostatic charging dynamics and paper mechanics are not solved.
INDEPENDENT NUMERICAL CHECKRK4 vs CLOSED FORM
RK4 engine—
Analytical reference—
Difference—
Constant-voltage step response at 0.35 s, independently integrated with fixed-step RK4 and compared with the closed-form damped-oscillator solution. Values are illustrative.
Illustrative educational model, not affiliated with any real institution or manufacturer.