For a horizontal Venturi with steady, incompressible single-phase water, continuity and Bernoulli's equation relate the static-pressure drop to the accelerated flow at the throat.
β = d / D; A₂ = πd²/4
Q = Cd A₂ √[ 2Δp / (ρ(1 − β⁴)) ]
v₂ = Q/A₂; Re₂ = ρv₂d/μ
h = Δp/(ρg)
Illustrative constants: D = 0.172 m, d = 0.088 m, ρ = 998 kg/m³, μ = 0.001 Pa·s, g = 9.80665 m/s².
Limitations: Water at a fixed reference condition; the calibration coefficient is an adjustable illustration, not a measurement. The model omits pipe friction outside the coefficient, nonuniform velocity fields, cavitation, entrained air, elevation differences and compressibility. Do not use it to size safety-critical equipment.
Verification: The flow is also found by bisection of Δp − ρ(Q/Cd)²(1/A₂² − 1/A₁²)/2 = 0, independently of the square-root evaluation.
Geometry and the instrument layout are stylised for legibility. An uncalibrated sensor or real meter requires its own dimensional and experimental data.