Radial heating experiment
Watch skin-effect energy deposition diffuse into the billet.
hotter steel coil / field
Cross-section · scaled20.0 °C
Thermal response · textbook modelMean and surface temperature
Absorbed power
2.80 kW
Skin depth
0.168 mm
Mean billet temperature
20.0 °C
Surface temperature
20.0 °C
Independent power check · analytical surface loss vs integrated radial source
Closed-form input / integrated cell source2.796 kW / 2.796 kW · 0.000%
The science · equations and assumptions
Electromagnetic heatingδ = √(2 / (ω μ σ)) · Rₛ = √(ω μ / (2σ))
Hᵣₘₛ = N I / ℓcoil · Pabs = η Rₛ Hᵣₘₛ² (2πRL)
Radial thermal diffusionρ cₚ ∂T/∂t = k (1/r) ∂/∂r (r ∂T/∂r) + q(r)
−k ∂T/∂r |R = h (Tsurface − Tambient)
The cylindrical billet is divided into 24 concentric finite-volume rings. Joule power is distributed exponentially with depth and normalized so its volume integral equals the analytical absorbed power. The numerical check on this page compares those two independent calculations.
Simplifications: fixed steel conductivity, permeability and heat capacity; uniform axial field; side-wall convection only; no phase change, radiation, end effects, coil losses or temperature-dependent magnetic transition. The coupling factor η is an illustrative geometry allowance, not a measured coil efficiency. The model is textbook / illustrative / scaled, not a process recipe.
Simplifications: fixed steel conductivity, permeability and heat capacity; uniform axial field; side-wall convection only; no phase change, radiation, end effects, coil losses or temperature-dependent magnetic transition. The coupling factor η is an illustrative geometry allowance, not a measured coil efficiency. The model is textbook / illustrative / scaled, not a process recipe.
Illustrative design, not affiliated with any real institution or manufacturer.