Hydrodynamic Journal Bearing Observatory
Watch a rotating shaft build its own supporting oil pressure inside a microscopic, converging clearance.
EQUATIONISOVISCOUS · STEADY
Model checks
Differences are relative to an independent reference calculation. The short-bearing comparison uses a separate slender calibration bearing (L/D = 0.15).
REFERENCE NOTESThe scienceEQUATIONS · ASSUMPTIONS · LIMITS +
A journal bearing supports a rotating shaft on a thin film of lubricant. The shaft centre is offset from the bearing centre, so the clearance forms a converging wedge. Surface motion entrains oil into that wedge; the narrowing gap raises pressure, and the integrated pressure can support a radial load.
Governing equation
∂/∂x (h³ ∂p/∂x) + ∂/∂z (h³ ∂p/∂z) = 6 μ U ∂h/∂x
Here x = Rθ, z is the axial coordinate, h is local film thickness, μ is dynamic viscosity and U = ωR is journal surface speed. The film geometry is h(θ) = c[1 + ε cos(θ)].
What is solved
The dimensionless Reynolds equation is discretised on a periodic circumferential grid and a finite axial grid. Successive over-relaxation iterates the pressure field. Pressure is clamped to non-negative gauge values using a half-Sommerfeld cavitation approximation.
The radial load is obtained by integrating pressure over the journal surface. The short-bearing calibration compares a separate slender case against its axial-flow-dominated closed-form approximation.
What is simplified
The lubricant is incompressible, Newtonian and isoviscous; flow is laminar and the film is thin. The model is steady, has no squeeze-film term, assumes rigid surfaces and applies ambient pressure at both axial ends.
Half-Sommerfeld clipping is not a mass-conserving cavitation model. The Couette friction estimate omits pressure-driven shear, thermal effects and inlet losses. The clearance in the cutaway is enlarged visually.
How to read the result
The eccentricity ratio and geometry are prescribed rather than solved from a coupled shaft-equilibrium calculation. Capacity divided by applied load is therefore a diagnostic margin, not a prediction of a real machine's operating equilibrium.
All user-set operating conditions are illustrative. The fixed 25 mm journal radius and surface roughness reference are illustrative constants, not specifications for a particular bearing.