Governing equations
Drive-line momentum
I dQ/dt = ρgHs − p − KQ|Q|
Air spring (polytropic)
p = Patm[(V0/(V0−W))n − 1]
Chamber continuity
dW/dt = Q − Qw − Qd
Orifice flow
Q = CdA√(2Δp/ρ)
Symbols
Q is drive flow, W is water displaced into the air vessel, Qw is waste flow and Qd is useful delivery flow.
Waste-valve motion
mẍ = Fpreload − ½ρ(Q/Apipe)²Adisc − cẋ
ρ = 1,000 kg/m³ TEXTBOOK · waterg = 9.81 m/s² TEXTBOOKPatm = 101,325 Pa TEXTBOOKn = 1.20 · Cd = 0.65 ILLUSTRATIVEDrive pipe: 8 m × 25 mm ILLUSTRATIVE
Independent numerical check
The pressure shown by the engine is checked again using a log/exponential form of the polytropic law. The two calculations use the same measured chamber displacement but separate numerical expressions.
ENGINE / CLOSED-FORM—
RELATIVE DIFFERENCE—
What is simplified
The drive pipe is a lumped inertance with Darcy–Weisbach friction; distributed wave travel, pipe-wall elasticity, cavitation, valve-seat impact, leakage and detailed air/water heat transfer are not resolved. The waste-valve force law is a reduced-order drag model. The chamber uses a fixed polytropic exponent.
Illustrative educational model, not affiliated with any real institution or manufacturer.