GOVERNING MODEL
Drive-pipe momentum
Ih Q̇s = ρgHs − p − RQs|Qs|
Ih = ρL/A; R = ρ(fL/D + K)/(2A²)
Water-column compressibility
Ch ṗ = Qs − Qw − Qd
Ch = AL/(ρa²)
Valve flow and air vessel
Q = CdA√(2Δp/ρ)
(Patm + pa)Vgγ = constant
Waste-valve motion
msẍ = Fopen − ρQs²/(2As) − csẋ
Valve travel x is constrained to 0–1 ILLUSTRATIVE.
INDEPENDENT WATER-HAMMER CHECK
The simulated surge is checked against the classical slow-closure estimate. For closure slower than a wave round trip, Δp ≈ 2ρLv/tc; otherwise the Joukowsky limit Δp = ρav is used.
ENGINE SURGE · ILLUSTRATIVE— bar
TEXTBOOK ESTIMATE · TEXTBOOK— bar
DIFFERENCE · ILLUSTRATIVE— %
Waiting for a complete waste-valve closure.
CONSTANTS & LIMITS
- Water density, ρ998.2 kg/m³ TEXTBOOK
- Gravity, g9.80665 m/s² TEXTBOOK
- Air exponent, γ1.40 TEXTBOOK
- Wave speed, a1,100 m/s ILLUSTRATIVE
- Discharge coefficient0.62 ILLUSTRATIVE
- IntegratorRK4 · fixed step TEXTBOOK
What is simplified: one-dimensional lumped pipe inertia and compliance; fixed friction and discharge coefficients; a single ideal-gas chamber; no distributed wave reflections, cavitation, leakage, pipe elasticity changes or valve impact damage. Valve spring and damping values are illustrative. The drawing is a scaled schematic, not a manufacturing plan.
Illustrative educational model, not affiliated with any real institution or manufacturer.