Hydraulic ram pump
Recover a fraction of low-head water energy by closing a waste valve and using the resulting pressure wave to lift water to a higher reservoir.
The operating cycle
Side elevation · schematicPressure pulse through one cycle
Head / timeDelivery head response
Efficiency / liftThe science — equations & assumptions
Water-hammer estimate. The Joukowsky pressure rise is attenuated when the valve closes more slowly than the pipe's wave round-trip time. The model uses a rigid-column drive velocity and a finite closure-time correction.
v₀ = √(2 g Hₛ / K)tᵣ = 2 L / aΔH = (a v₀ / g) · min(1, tᵣ / t꜀)Hₚₑₐₖ = Hₛ + ΔHQₚ = Cᵈ Aᵥ √(2 g · max(0, Hₚₑₐₖ − Hᵣ))η = ρ g Qₒ H_d / (ρ g Qᵢ Hₛ)Cycle approximation. A smooth half-sine-squared pressure pulse represents the transient. A pulse-shape factor estimates delivered volume; an energy ceiling prevents the model from transferring more than 72% of the available drive hydraulic energy. Real valve dynamics, pipe friction distribution, gas-chamber compliance, cavitation and water-column separation are not resolved.
All values are illustrative design values, not manufacturer performance data. Water density is fixed at 998 kg/m³ and g at 9.81 m/s².
Illustrative design, not affiliated with any real institution or manufacturer.