Governing equations TEXTBOOK
Drive-column acceleration
dV/dt = (g/L) [Hs − K V²/(2g)]
Water hammer at rapid closure
Δp = ρ a ΔV · ΔH = a V/g
Air cushion (polytropic compression)
p Vairγ = constant
Delivered energy efficiency
η = Qd Hd / (Qs Hs)
Assumptions ILLUSTRATIVE
- The drive pipe is a one-dimensional rigid water column during acceleration; Darcy–Weisbach and local losses are combined into K.
- The waste valve closes at a user-set calibrated trip speed. Its detailed mass, spring and fluid-force motion is not resolved.
- The pressure wave is represented by a damped exponential characteristic response; the delivery check valve passes drive flow only while pump head exceeds chamber head.
- The air vessel is well mixed and follows a polytropic law with γ = 1.40. Delivery-line losses are represented by a fixed outlet resistance.
Textbook constants: g = 9.81 m/s²; ρ = 1,000 kg/m³; atmospheric pressure = 101,325 Pa. Numerical settings are illustrative, not a construction design.
Illustrative educational model, not affiliated with any real institution or manufacturer.