Cycle anatomy & pressure trace
Independent pressure check
Energy & cycle balance
The science · assumptions and equations
Drive-line acceleration. While the waste valve is open, the rigid-column approximation gives dV/dt = g A Hs / L. The selected closure velocity sets the end of this acceleration ramp.
Water hammer. A rapid velocity change produces the ideal Joukowsky head rise ΔH = a · Δv / g. The pulse is represented here by an exponential decay, H(t) = Hs + ΔH · exp(−t/τ).
Delivery valve. When chamber head exceeds delivery head plus a 0.30 m illustrative cracking allowance, a simplified orifice relation estimates flow: Qd = Cd Av √(2g · max(H − Hd − Hcrack, 0)). Numerical integration estimates pulse volume; mass and an 82% hydraulic-energy ceiling bound the delivered volume.
Cycle metrics. Drive volume is approximated by the triangular acceleration ramp. Cycle time includes the acceleration ramp and a 4.5τ pressure/recovery window. Mean flows and hydraulic efficiency are calculated from per-cycle volumes.
Simplifications. The model omits distributed elastic wave propagation, pipe friction transients, valve inertia, chamber air compression, check-valve chatter and detailed refill dynamics. Wave speed and damping are effective inputs; visual motion is scaled for teaching.
Labels: equations are textbook idealisations; the transient pulse and valve closure are illustrative; the cutaway is scaled.