Water hammer · first-surge study
Hydraulic ram pump laboratory
Follow the pressure wave created when a waste valve snaps shut. Tune the drive line, then inspect the same scenario in a 3D cutaway.
01 / Hydraulic circuit
SCHEMATIC · NOT TO SCALEFLOW DIRECTION → · PULSE TRAVELS ALONG DRIVE PIPE
Wave speed—m/s in pipe
Incident surge—bar gauge
Round trip—ms · 2L / a
Drive flow—L/s steady estimate
Chamber pressure—bar absolute
02 / Valve pressure trace
IDEALIZED FIRST-RETURN RESPONSEPressure rise · bar gaugeOne round trip: — ms
The science · equations, assumptions and independent checks
Elastic wave speed
a = √[(K / ρ) / (1 + KD / Et)]
Thin-wall elastic-pipe correction; wall thickness is estimated as 7.5% of internal diameter for this illustrative HDPE line.Joukowsky surge
Δp = ρ a Δv · min(1, 2L / atc)
The finite-closure factor limits the instantaneous-closure result when the valve closes more slowly than one round-trip wave time.Initial drive flow
v = √[2gH / (fL/D + Km)] · Q = vA
A steady Darcy–Weisbach estimate with fixed illustrative friction and minor-loss coefficients.Air-chamber compression
P₁V₁γ = P₂V₂γ
The first-pulse volume is estimated as Q times the shorter of closure time and wave round-trip time. Compression is capped at 25% of gas volume.Independent checks will appear here.
Limitations: this is a first-surge teaching model, not a full transient method-of-characteristics solver. It omits valve impact mechanics, distributed friction, cavitation, leakage, reservoir dynamics and the complete delivery-cycle efficiency. The pressure trace is a damped first-return illustration using the calculated round-trip period.
Illustrative design, not affiliated with any real institution or manufacturer.