MMY SIMULATOR
ENGINEERING LAB INTERACTIVE MODEL
HYDRAULICS / PRESSURE PHYSICS

When a Cylinder Multiplies Pressure

A sealed hydraulic chamber can develop a pressure higher than the pump supply. Explore the force balance that creates it.

LIVE MODEL
CUTAWAY / SIDE VIEWDouble-acting cylinder · rod-side port sealed
PRESSURE BUILDING
The supply pushes the piston right. Trapped oil resists compression in the smaller annular chamber.
SUPPLY CHAMBER TRAPPED OIL STEEL / ROD PISTON TRAVEL SCALED
ILLUSTRATIVE INPUTS

Change one variable at a time

Slider settings and the 250 bar warning threshold are illustrative. Areas, forces and pressures are calculated from textbook relations; piston travel in the drawing is schematic and not to scale.

RUNNING · FIXED 1/120 s STEP
↗Run the pressure test to compare the simulated rod-side pressure with the ideal force-balance prediction.
MODEL INTEGRITY

Three independent checks

CHECKING
✓
Area closurepiston area = rod + annulus
0.00%
✓
Bulk-modulus slopefinite difference vs. analytic
0.00%
✓
Equilibrium solverclosed form vs. bisection
0.00%

Relative differences are evaluated from the current control settings. All three checks should remain below 0.1%.

MODEL NOTESThe science+

Why pressure rises

The cap-end pressure acts on the full piston area. The trapped rod-side oil acts on the smaller annular area. If the piston moves into the sealed chamber, its volume shrinks and its pressure rises until the opposing hydraulic force balances the supply force and external load.

Ap = πD² / 4   ·   Aa = π(D² − d²) / 4
Fnet = psAp − prAa − Fload
pr = p0 + β ln[L / (L − x)]
ptarget = (psAp − Fload) / Aa

What the model assumes

  • One-dimensional piston motion with a constant cap-end gauge pressure.
  • The rod-side port is perfectly sealed; no leakage or relief valve is modelled.
  • A constant effective bulk modulus represents oil, entrained air and line compliance together.
  • The piston follows an overdamped first-order response with a 0.45 s illustrative time constant. The update is integrated exactly at a fixed 1/120 s step.
  • Stroke is limited to 85% of the initial trapped-chamber length.

The 250 bar component rating is an illustrative warning threshold, not a specification. The piston-travel graphic is schematic and dimensions are not to scale. This educational model is not a hydraulic design or safety tool.

Made with 🤖 ChatGPT