Governing equations
The pipe is represented as a lumped water column with inertance. The gas pocket follows a polytropic law:
I dQ/dt = Pup − Pg − R Q|Q|
dVg/dt = −(Qpipe − Qvalve)
Pg Vgγ = constant
Textbook constants: water density 998 kg/m³, atmospheric pressure 101,325 Pa, and air exponent γ = 1.40. Illustrative settings: supply pressure 6.00 bar absolute, downstream pressure 1.01325 bar absolute, and a 12.0 bar absolute vessel rating.
What is simplified
The pipe is a single inertial element, not a distributed acoustic wave model. The valve's opening falls linearly during closure. Pipe losses use a constant Darcy friction factor. The vessel gas is uniform in pressure and temperature and follows a polytropic relation. Water compressibility, pipe-wall elasticity, branch losses, heat transfer, cavitation, and detailed valve mechanics are omitted.
What is illustrative
Supply and downstream pressures, the vessel rating, preset values, and all slider ranges are illustrative. The vessel drawing is a cutaway schematic, not a dimensional engineering drawing. The rating warning is a model threshold; the simulation does not predict rupture or certify a real installation.
How to read the experiment
The theory estimate linearises the gas spring around its closed-valve equilibrium and assumes an instantaneous closure with no damping.
Ppeak,lin ≈ Pup + C−1 √[(V0−Veq)² + (Q0/ωn)²]
The measured result comes from the nonlinear RK4 model with the selected valve-closing time and pipe friction. Their difference shows where the estimate’s assumptions matter.
Educational model only. It is not a design, safety, or pipe-sizing tool.
Read the full field note ↗