Voltage response
η / %Collection efficiency as applied voltage changes.
Particle-size response
w / mm·s⁻¹Electrical migration velocity with Cunningham slip correction.
Flow sensitivity
η / %Higher throughput reduces the available collection time.
05 The science · equations and simplifications+
1. Electric field
E = V / s, where V is applied voltage and s is the plate spacing.
2. Particle charge
qₚ ≈ 3πε₀dₚ²E × 0.65. This uses a simplified field-charging estimate for a spherical particle.
3. Migration velocity
w = qₚ E Cc / (3π μ dₚ). The Cunningham correction Cc accounts approximately for non-continuum slip at small particle sizes.
4. Collection efficiency
η = 1 − exp(−wA/Q). This idealised Deutsch–Anderson relation assumes an effective collection area A and uniform gas flow Q.
The model omits re-entrainment, back corona, non-uniform flow, particle-size distributions, turbulence and electrical breakdown. It is for learning and parameter intuition, not plant sizing or compliance decisions.
Illustrative design, not affiliated with any real institution or manufacturer.