A / VOLTAGE RESPONSEη vs applied voltage
20–70 kVOther parameters held fixed
A charged aerosol meets an electric field. Follow the particles, tune the collector, and measure what reaches the plates.
Each curve recalculates from the same shared model. Move a control to see how the response shifts.
E = V / gApplied potential divided by the effective electrode gap.
qsat = 3π ε₀ dp² EPauthenier saturation-charge approximation for a conducting sphere; q = fq qsat.
w = q E Cc / (3π μ dp)Stokes electrical drift with Cunningham slip correction.
η = 1 − exp(−w A / Q)Deutsch–Anderson ideal collection efficiency.
TEXTBOOK Deutsch–Anderson and Stokes-drift forms · ILLUSTRATIVE charge fraction and effective gap · SCALED animated geometry.