ENGINEERING OBJECT / ELECTROSTATIC SEPARATION

Collector anatomy

A walk through the field zone: identify the electrodes, follow the aerosol stream, and separate the machine into its working assemblies.

CUTAWAY / PROCESS VIEW

Parallel-plate precipitator

SCALED ASSEMBLY
GAS FLOW →
HIGH QUALITY / WEBGL
FIG. 02 / INTERACTIVE ASSEMBLYDrag to orbit · scroll to zoom · select a part to inspect
LIVE MODEL OUTPUT0.0113 fCeffective particle charge
SLIP CORRECTION1.066Cunningham factor
INDEPENDENT CHECK54.92%Euler / 20,000 steps
ANALYTICAL COMPANIONOpen 2D graph lab ↗Live plots + CSV export
MODEL NOTESEquations, assumptions & limits+
FIELDE = V / g

Potential divided by effective electrode gap.

CHARGINGqsat = 3π ε₀ dp² E

Pauthenier field-charging approximation for a conducting sphere; q = fqqsat.

MIGRATIONw = q E Cc / (3π μ dp)

Stokes electrical drift with Cunningham slip correction.

COLLECTIONη = 1 − exp(−w A / Q)

Deutsch–Anderson ideal collection efficiency.

Interpret with care

  • Uniform effective field, monodisperse spherical aerosol and fixed air properties near 20 °C / 1 atm.
  • Charge fraction and electrode gap are illustrative calibration parameters.
  • Re-entrainment, back-corona, turbulence, agglomeration and spatial field distortion are omitted.
  • The 3D geometry is a scaled educational assembly, not a construction drawing.

TEXTBOOK: standard model forms · ILLUSTRATIVE: charging factor · SCALED: geometry and particle animation.

Made with 🤖 ChatGPT · Three.js