Displacement and lift
v = rω · chain speed from sprocket radius and angular speed.
Ap = (W − 2c) × 0.18 m · swept paddle face area; the bottom gap is fixed at 10 mm (textbook test geometry).
Qideal = Ap v and Q = ηv Qideal · swept and delivered flow.
Ph = ρgQH · useful hydraulic power.
Illustrative slip calibration
ηv = clamp(0.94 exp[−0.134(c/10 mm) − 0.65(s/dp − 1.05)² − 0.30(H/L)] × fsub, 0.18, 0.94).
fsub = 0.72 + 0.28(I − 60%)/40% · a compact intake-immersion factor. This fit is illustrative, not a universal pump law.
Drive dynamics
J dω/dt = τdrive − τpump − τb − cω. At rest, a 1.8 N·m breakaway margin (illustrative) must also be cleared.
τpump = ρgAp rH / ηm · mean load torque from the swept water volume.
ηoverall = Ph / (τdrive ω) · live shaft-to-water efficiency.
Model assumptions
The chain, paddles and water are represented by one rotational degree of freedom. The drive loss is a lumped bearing-plus-viscous term. Splash, changing water depth, chain elasticity, tooth impacts and transient pocket filling are omitted.
Constants: ρ = 1,000 kg/m³, g = 9.81 m/s², paddle height = 0.18 m, flume depth = 0.19 m and L = 4.1 m (textbook references); r = 0.14 m, ηm = 0.62, J = 0.55 kg·m², τb = 0.6 N·m and c = 0.68 N·m·s and the 1.8 N·m breakaway margin (illustrative). The historical test geometry and operating guidance are labelled textbook reference.
Illustrative educational model, not affiliated with any real institution or manufacturer.
Historical basis: FAO, Water lifting devices, section 3.6.6, “Water Ladders and Dragon-Spine Pumps”.