Historical principle
Cowper’s regenerative stove was patented in 1857. Its key innovation was to store heat from furnace gas in refractory checkerwork, then reverse the flow so the incoming blast recovered that heat. Later designs refined the checker passages and chamber arrangement.
Regenerative heat exchange
Each axial checker cell exchanges heat with a passing fluid packet. The exact two-capacitance solution for one fixed step is:
Qᵢ = (Tᶠ − Tˢᵢ) · CᶠCˢ/(Cᶠ + Cˢ) · [1 − e−UAᵢΔt(1/Cᶠ + 1/Cˢ)]
Tᶠ′ = Tᶠ − Qᵢ/Cᶠ · Tˢᵢ′ = Tˢᵢ + Qᵢ/Cˢ
Bed losses and performance
Qloss,i = Cˢ(Tˢᵢ − Tamb)[1 − e−Uloss,iΔt/Cˢ]
Ebed = Σ mᵢcp,s(Tˢᵢ − Tamb)
ηblast = Qblast/(Qblast + Qloss)
Passage trade-off
Δp = Δpref(ṁ/ṁref)²(gref/g)³
Narrower passages raise the modelled heat-transfer conductance modestly while increasing flow resistance sharply. The conductance scaling is an illustrative fit, not a universal correlation.
Model constants
- Checker brick heat capacity840 J kg⁻¹ K⁻¹ illustrative
- Flue-gas heat capacity1,120 J kg⁻¹ K⁻¹ illustrative
- Blast-air heat capacity1,050 J kg⁻¹ K⁻¹ illustrative
- Ambient reference25 °C illustrative
- Axial cells / fixed step24 / 0.25 s scaled
- Reference conductance360 kW K⁻¹ scaled
- Reference pressure loss1.8 kPa scaled
What is simplified
The checker bed is a one-dimensional stack of lumped refractory cells. Fluid packets pass through the cells in sequence; axial conduction, radiation between bricks, combustion chemistry, moisture, fouling, valve leakage, refractory ageing and the detailed combustion-chamber pressure field are omitted. The combustion chamber and connecting dome are treated as low-loss transfer passages. The initial bed is a preheated illustrative temperature profile. Geometry and operating values are scaled, not a reconstruction of one historical stove.
Illustrative educational model, not affiliated with any real institution or manufacturer.