Power systems · coastal operations

Coastal Gridwatch

Balance a wind-powered island grid as weather and demand shift around you.

SEED 731904 · DUSK / WINDY
FIXED ISOMETRIC · TEEN
Grid frequency
50.00 Hz
Operating time
00:00
Wind state
BREEZY
Gust front approachingWind output is rising.
T+ 000.0 s
Frequency
50.00Hz
Nominal target 50.00 Hz
Wind output
—MW
3 turbine array
Battery power
0.00MW
Idle · droop control
Battery charge
76%
Reserve target 25%
Demand
—MW
Flexible demand online
Power balance
—MW
Stable window 100%
Power dispatch
Generation, demand & battery · MW
LIVE
WindDemandBattery
Grid frequency response
Measured signal & analytic projection · Hz
50 Hz
Live frequencyAnalytic projection
The science · model, assumptions & equations

1 · Wind turbine power

A = πr²
Pwind = min(Prated, ½ ρ A Cp v³) × N

ρ is air density (kg/m³), A is swept area (m²), Cp is a dimensionless power coefficient, v is wind speed (m/s), and N is the number of turbines. The result is converted from watts to megawatts.

2 · Grid frequency response

Pimbalance = Pwind + Pbattery − Pload
df/dt = f₀ Pimbalance / (2 H Sbase) − D(f − f₀)

Frequency f is in hertz; power is in megawatts; H is an approximate inertia constant in seconds; D is a damping coefficient in s⁻¹. A single-bus first-order model is used to make the response understandable.

3 · Battery energy

dSOC/dt = −Pbattery / Ecapacity × 100 / 3600

Positive battery power means discharge. Negative power means charging. The controller applies a simple frequency-droop rule and respects minimum and maximum state-of-charge limits.

Solver & assumptions

State updates use a fixed 1/120-second semi-implicit Euler step with an accumulator. The dashed analytic curve assumes today's net power imbalance stays constant; it is an approximate short-horizon reference, not a second simulation. Wind density is fixed, turbines are aggregated, and the battery uses an idealised energy balance. Weather and demand changes are scripted educational events.

What this model leaves out

  • No AC power-flow, voltage, reactive power or transmission-line constraints.
  • No blade pitch, wake interaction, generator transients or cell-level battery effects.
  • Demand response is a simplified temporary load reduction.

Use: educational exploration only; not for operating a real electricity network.

Made with 🤖 ChatGPT · Three.js