How water makes a blast
A falling water column creates a low-pressure region at the air inlets. Air is entrained, carried downward as bubbles, then separated in a receiver. A water seal holds the compressed air while the water escapes through its outlet.
Equations in this model
- Pipe velocity: v = Qw / A
- Reynolds number: Re = ρ v D / μ
- Head loss: hL = (f L/D + K) v²/(2g)
- Seal pressure: pg = min(ρghs, ρg(H − hL))
- Isothermal air work: Pair = patm Qair ln(pabs/patm)
- Hydraulic input: Phyd = ρgQwH
Constants and assumptions
Water density ρ = 998.2 kg/m³ and viscosity μ = 1.002 mPa·s at about 20°C, and standard gravity g = 9.80665 m/s² (textbook). Pipe roughness 0.15 mm, minor-loss coefficient K = 1.8, bubble-capture fraction 82%, and energy-transfer ceiling 85% (illustrative).
Assumptions and limits
Water is incompressible; the downpipe is treated as a steady, single-phase conduit for the head-loss estimate. Air entrainment and bubble capture are represented by an adjustable ratio and an illustrative 82% capture factor. Air compression is treated as isothermal. An illustrative 85% energy-transfer ceiling prevents impossible outputs. The machine balance is solved algebraically at steady state; moving tracers use a fixed 1/60 s timestep (scaled). The model does not resolve two-phase turbulence, bubble-size distributions, gas dissolution, or the detailed receiver geometry.
Historical reference (textbook): a documented Catalan trompe with a fall of nearly 3 m and a receiver about 0.6 m deep produced a measured blast near 1.2 kPa; published analysis places forge-trompe conversion near 15%. The default model gives 14.3% (illustrative) and uses an equivalent seal-head abstraction, not a dimensionally exact reconstruction.
Illustrative educational model, not affiliated with any real institution or manufacturer.