05 / TRADE-OFF MAP
A and B · log scaleCapillary head versus permeability
Illustrative wick archetypes. Their pore radius and permeability are specified independently rather than inferred from one another.
CAPILLARY LOOP HEAT PIPE · ARCHITECTURE STUDY
A fine pore can create a stronger meniscus, while a more open structure can move liquid with less resistance. Compare the trade-off.
Illustrative wick archetypes. Their pore radius and permeability are specified independently rather than inferred from one another.
ΔPcap ∝ 1/r while ΔPw ∝ 1/K.
Smaller pores increase capillary pressure, but the permeability of a real wick depends on pore network geometry, porosity, tortuosity and manufacturing route.