Apply a heat step and follow the evaporator's thermal inertia. The transport ceiling clips the heat removed when the capillary pressure budget is exhausted.
01 / LIVE OSCILLOGRAM
Evaporator response
READY
Wall temperature Heater input Transported heat
ELAPSED TIME0.0s · simulation time
EVAPORATOR WALL—°C · lumped node
TRANSPORTED HEAT—W · capped by loop
03 / THERMAL MODEL
First-order energy balance
C dT/dt = Qin − Qout
THERMAL CAPACITANCE—STEADY WALL ESTIMATE—
The evaporator is represented as one thermal node. Heat rejection is limited by the capillary transport capacity calculated from the pressure budget.
LAB NOTE
The science
Lumped transient model
Cth dT/dt = Qin − min[(T − Tsink)/Rth, Qcap]
A fourth-order Runge–Kutta step advances the thermal state. The heater ramps linearly over 45 seconds; fluid properties are held at the selected operating temperature.