A bridge can be modelled, for one dominant vibration mode, as a mass on a spring with a damper.
m ẍ + c ẋ + kx = F₀ sin(ωt)
m is effective moving mass, c is viscous damping, k is modal stiffness, and F₀ and ω describe the repeating force. The natural angular frequency is ωₙ = √(k/m), or fₙ = ωₙ/(2π).
X = F₀ / √[(k − mω²)² + (cω)²]
This steady-state amplitude grows when the forcing frequency approaches the natural frequency. Damping limits the peak and changes the phase lag between the force and the deck response.
Numerical method. The live motion uses fixed-step fourth-order Runge–Kutta integration. The verification run starts from rest, integrates the same equation independently, then measures amplitude, phase and average power over its final cycles.
Simplifications. This is a single-degree-of-freedom, linear model. It omits multiple bridge modes, torsion, nonlinear cables, wind–structure feedback, traffic detail, foundation motion and changing material properties. The bridge drawing is schematic; the deck motion is visually scaled.
Interpretation. The envelope shown is an illustrative teaching threshold, not a code limit, safety assessment or prediction for any real bridge. Real structures require site-specific data, validated models and qualified engineering review.
This independent educational exhibit is not affiliated with a bridge owner, engineering institution or standards body.