Read the cooldown trace.

Fit a first-order model to synthetic thermistor readings. The estimated time constant turns temperature data into a conductance estimate.

Measured temperature and fitted model

Blue points: noisy readings · red line: regression fit

Cooling transient
Estimated time constant—s · from log-linear fit
Estimated conductance—W/K · C / τ
Fit quality—R² · regression
Readings used—samples
Reference UA —Estimated error —Sensor resolution 0.05 °C
Time (s)Measured (°C)Model (°C)Residual (°C)
Independent check — analytic convection solution.
The science — equations and simplifications

The model treats the battery module as one uniform thermal node. Electrical heating is ohmic; heat leaves through an effective module-to-coolant conductance and thermal radiation.

C · dT/dt = I²R − UA(T − Tₐ) − εσAₛ[(T+273.15)⁴ − (Tₐ+273.15)⁴]

C = m cₚ is thermal capacitance (J K⁻¹); R is resistance (Ω); UA is effective conductance (W K⁻¹); ε is emissivity; σ is the Stefan–Boltzmann constant. Current and resistance are held constant within each time step.

Simplifications: a single lumped temperature, no cell-to-cell gradients, no reversible/entropic heat, no temperature-dependent resistance, no coolant warm-up along the channel, and no phase change. The flow-to-UA relation in the design map is an illustrative power law, not a manufacturer correlation.

Readouts are illustrative values from a textbook-style lumped model, not validated pack predictions. The model is for learning and comparison, not battery safety or engineering sign-off.

Illustrative design, not affiliated with any real institution or manufacturer.

THERMAL ATLAS · FAMILY STUDY 01Scientific model / not a product specification