A Barker's Mill is a reaction turbine: water enters a hollow vertical shaft and leaves through tangential outlets at the ends of radial arms. The jet's change in angular momentum applies torque to the rotor.
Jet speedu = √(2 g H)
Flow rateQ = Cd A u
Reaction torqueτt = ρ Q r (u − rω)
Rotor motionI dω/dt = τt − τL − bω
Hydraulic efficiencyη = τL ω / (ρ g Q H)
The ideal fixed-flow model has a 50% maximum shaft-power fraction: the remaining energy leaves with the water. The numerical rotor equation is integrated with fixed-step fourth-order Runge–Kutta (RK4).
Simplifications: incompressible water, constant discharge coefficient, equal outlets, constant supply head, fixed flow independent of rotor speed, and a lumped rotor inertia. Centrifugal pumping in the arms, turbulence details, leakage, and changing tailwater level are omitted. The historical machine was more complex than this teaching model.
TEXTBOOK g = 9.80665 m/s²; ρ = 998 kg/m³ (water near 20 °C)ILLUSTRATIVE Cd = 0.92; I = 0.060 kg·m²
Illustrative educational model, not affiliated with any real institution or manufacturer.
Historical references: ASME landmark report, “Barker Turbine / Hacienda Buena Vista”; Science Museum Group collection, “Whitelaw's Reaction Turbine or improved Barker's Mill”.