How the machine worked
Stationary pumping engines exhausted air from a cast-iron pipe laid between the rails. A piston inside the pipe was linked to the leading carriage by an iron arm passing through a longitudinal slot. A hinged leather flap resealed the slot behind it. Atmospheric pressure on the rear face of the piston supplied the thrust.
Equations in this model
A = πD² / 4
Fp = Δp · A
m · dv/dt = Fp − Crrmg cosθ − mg sinθ − ½ρCdAfv²
d(Δp)/dt = (Δpset − Δp)/τ − λΔp
The pressure equation is integrated with fixed-step fourth-order Runge–Kutta at 1/120 s per step (illustrative numerical step). Its independent check uses the exact first-order solution: Δp(t) = Δpeq + [Δp(0) − Δpeq]e−(1/τ+λ)t, where Δpeq = Δpset/(1+λτ).
Constants and assumptions
- Textbook constants: g = 9.80665 m/s²; air density ρ = 1.225 kg/m³; atmospheric pressure = 101.325 kPa.
- Illustrative assumptions: rolling coefficient 0.012, drag coefficient 0.9 and frontal area 7.5 m². Train mass, gradient, leakage and pump response are adjustable.
- The tube is treated as one well-mixed pressure section. Pumping is represented by a first-order pressure response; valve opening, spatial pressure waves, junctions, braking, and pump energy consumption are not resolved.
- The carriage and pipe drawings are schematic, not dimensionally scaled. The 0.381 m default pipe diameter is the textbook 15-inch nominal size reported for the South Devon installation.
The South Devon atmospheric line operated briefly in 1847–48. Leather-flap leakage and maintenance were among the system's practical weaknesses.
Illustrative educational model, not affiliated with any real institution or manufacturer.