Same load. Different path.

Both modules see the same electrical demand and thermal mass. Only the cooling path changes.

Temperature comparison

Air cooling in amber · liquid cooling in blue-green

Matched workload

Air cooling · A

—

Peak temperature · °C

—

Liquid cooling · B

—

Peak temperature · °C

—

Liquid advantage—°C lower peak
Air time constant—s · C / UA
Liquid time constant—s · C / UA
Electrical heat—W · same input
Independent check — analytic convection solution.
The science — equations and simplifications

The model treats the battery module as one uniform thermal node. Electrical heating is ohmic; heat leaves through an effective module-to-coolant conductance and thermal radiation.

C · dT/dt = I²R − UA(T − Tₐ) − εσAₛ[(T+273.15)⁴ − (Tₐ+273.15)⁴]

C = m cₚ is thermal capacitance (J K⁻¹); R is resistance (Ω); UA is effective conductance (W K⁻¹); ε is emissivity; σ is the Stefan–Boltzmann constant. Current and resistance are held constant within each time step.

Simplifications: a single lumped temperature, no cell-to-cell gradients, no reversible/entropic heat, no temperature-dependent resistance, no coolant warm-up along the channel, and no phase change. The flow-to-UA relation in the design map is an illustrative power law, not a manufacturer correlation.

Readouts are illustrative values from a textbook-style lumped model, not validated pack predictions. The model is for learning and comparison, not battery safety or engineering sign-off.