| Flat beam | Arch | |
|---|---|---|
| Thickness needed | ||
| Stone per m of strip | ||
| Peak stress | ||
| Horizontal push on walls | ||
| Mid-span sag (real) | - |
Per 1 m strip of roof, span L = 10 m, stone weight 24 kN/m3, allowable tension (modulus of rupture) 2 MPa, allowable compression 10 MPa, Young's modulus 30 GPa. These are rounded, illustrative values for sound stone masonry.
Flat beam (simply supported, Euler-Bernoulli). Self-weight grows with depth h, so h is solved, not guessed:
w = q + g*h M = w L^2 / 8 sigma = 6 M / h^2 <= sigma_t => sigma_t h^2 - 0.75 g L^2 h - 0.75 q L^2 = 0 sag = 5 w L^4 / (384 E I), I = h^3/12
Even with q = 0 the stone beam needs about 0.9 m of depth just to carry itself, which is why unreinforced stone never spanned 10 m flat. The sag drawn is multiplied by a stated factor; the real value is shown in the table.
Arch. A parabola y = 4 f x (L - x) / L^2 is the exact funicular (zero bending) shape for load that is uniform per horizontal metre:
H = w L^2 / (8 f) horizontal thrust V = w L / 2 vertical reaction N_max = sqrt(H^2 + V^2) at the springing w = q + g t k (k = arc length / span) Half-span live load: M = q L^2 / 64 (three-hinged parabolic arch) sigma = N_max / t + 6 M / t^2 <= sigma_c
t is found by bisection, with a practical minimum of 0.12 m. The thrust line stays inside the middle third of the section when e = M/N <= t/6; the page reports whether that holds.
Honest limits. Self-weight of the arch is treated as uniform per horizontal metre (slightly wrong for steep sections); buckling, wind, foundation movement and joint sliding are ignored; real arches are checked with thrust-line limit analysis (Heyman). The walls must resist H, so the arch also needs buttresses or ties: the thrust is the price of its thinness. Real snow load is about 1 to 3 kN/m2; the slider goes higher to show the trend.