Centrifugal pump cavitation
Inspect the suction eye, impeller, volute and drive train as the operating point changes.
The science / equations and assumptions
Q is in m³/h; heads and elevations are in metres. The quadratic coefficients K are in m/(m³/h)². The operating point is the positive pump/system-curve intersection. Atmospheric pressure uses a standard-atmosphere approximation, while water density and vapour pressure vary with temperature.
The characteristic curves are illustrative fits, not a manufacturer's map. NPSHr is a simplified 3% head-drop requirement. Bubble density is a qualitative visual proxy for reduced NPSH margin, not a CFD prediction. The 1.5 m reserve band is a display threshold only, not a universal engineering acceptance criterion.
All computed values are illustrative model outputs, not vendor-certified performance data. Illustrative design, not affiliated with any real institution or manufacturer.