Air moves through a mine because a fan creates a pressure difference. Every airway has a resistance R that turns flow Q into pressure drop. Two headings in parallel share the flow so that they have the same pressure drop. The fan curve and the system curve cross at the operating point. Methane released at the face is carried away by the airflow and its concentration follows a first-order dilution law.
Equations
- Atkinson law
p = R Q², withR = k P L / A³, rubbing factor k, perimeter P = 4√A, length L, area A. - Series add resistances, parallel add conductances
1/√Rpar = Σ 1/√Ri. - Regulator (orifice)
R = ρ / (2 Cd² Ao²)with Cd = 0.65. - Fan curve
p = a n² − b Q²with relative speed n (fan laws: Q ∝ n, p ∝ n², power ∝ n³). - Operating point
p = a n² / (1 + b C²),Q = C √p, with total conductance C = 1/√Rsys plus the door. - Methane
V dC/dt = q − QA C, steady valueC = q / QA, time constantτ = V / QA.
Checks run in the page
- The fan and system curves are intersected by bisection and compared with the closed form.
- The split between the two headings is solved at a given pressure and compared with the equivalent parallel resistance.
- The fan laws are checked by solving the operating point at two speeds.
- Methane dilution is integrated with RK4 and compared with the exponential solution.
Honest simplifications
Air is treated as incompressible with constant density 1.2 kg/m³, turbulent flow with a fixed rubbing factor, no natural ventilation pressure, no fan efficiency curve, and a single mixed gas volume per heading. Real ventilation planning uses network software and measured resistances. Methane limits shown (1 % alarm, 1.25 % power-off) are teaching values.
What to try
- Press Regulator closed and see how the flow in heading B drops while heading A gains.
- Press Door open and watch the fan deliver more air that does no useful work.
- Press Gas surge and then raise the fan speed to see the dilution time constant shrink.