Tailings Thickener

2D companion of the tailings thickener sim: a settling column and a continuous thickener solved as a conservation law, with the limiting-flux construction that sets the tank area.

Switch to 3D

Presets

Playback

Apparatus

Model checks

The science

What is modelled

Fine tailings settle slowly, and the more crowded they are the slower each particle falls because the displaced water has to flow up between them. This hindered settling makes the solids flux through a horizontal plane peak at a certain concentration and fall again at higher concentrations. In a continuous thickener the bottom withdrawal adds a flux, and the feed can only be handled if it stays below the lowest value of the total flux between the feed and the underflow concentration, the limiting flux. Above that the bed rises and solids escape in the overflow.

Equations

  • Stokes velocity v0 = d² (ρs − ρw) g / (18 μ), with the flocculant making aggregates larger by the chosen factor.
  • Hindered settling flux f(φ) = v0 φ (1 − φ/φmax)n.
  • Conservation law ∂φ/∂t + ∂/∂z [ f(φ) + v φ ] = source, bulk velocity v downward below the feed (underflow) and upward above it (overflow), solved by a conservative Godunov scheme.
  • Kynch: in a batch column the clear-liquid interface falls at f(φ0)/φ0 = v0 (1 − φ0/φmax)n until the bed meets it.
  • Limiting flux GL = minφf ≤ φ ≤ φu [ f(φ) + qu φ ]; the feed solids flux qf φf must not exceed it, and the required area is the solids load divided by GL.

Checks run in the page

  • The terminal speed of a sphere from a drag equation integration against Stokes' formula.
  • The batch interface speed from the numerical scheme against the Kynch value.
  • Solids mass conservation: feed in, underflow and overflow out and the change in the tank.
  • The underflow concentration (or the overflow loss) from a long run against the limiting-flux prediction.

Honest simplifications

One dimension, no compression of the bed, a single particle size, constant fluid properties, instantaneous flocculation, a plain feed well and a rake shown only as a picture. Real thickeners are designed from batch and pilot tests with compression and rheology included.

What to try
  • Press Batch settling test and watch the interface fall at a constant rate, as Kynch predicted.
  • Press Overloaded and see the bed rise past the feed and solids spill into the overflow.
  • Press Flocculated to raise the settling rate and lift the limiting flux.
Solids concentration against depth
Mud line and bed height against time
Flux against concentration: settling, total, limiting and feed
Solids in the tank and solids leaving