Centrifugal pump cavitation
Find the operating point, then follow the pressure margin that protects the impeller from vapour formation.
The science / equations and assumptions
Q is in m³/h, head and elevation are in metres, pressure is in pascals, and ρ is water density. The quadratic coefficients K are in m/(m³/h)². The operating point is the positive intersection of the pump and system curves. Atmospheric pressure uses a standard-atmosphere approximation; water density and vapour pressure vary with temperature.
The pump and NPSHr curves are illustrative characteristic fits, not a manufacturer's performance map. The NPSHr correlation represents a simplified 3% head-drop requirement. The animated cavitation indicator is an explanatory visual proxy, not a CFD prediction or a guarantee of safe operation. The 1.5 m reserve band is a display threshold only, not a universal engineering acceptance criterion.
All computed values are illustrative model outputs, not vendor-certified performance data. Illustrative design, not affiliated with any real institution or manufacturer.