Hydraulic systems labInteractive engineering series · 2D analytical view
Cavitation & performanceOperating safely

Centrifugal pump system

Cross-section schematic · animated flow path · operating point linked to the curves

SCHEMATIC / NOT TO SCALE
SOURCE TANK → SUCTION LINE → IMPELLER → DISCHARGE

Head–flow operating map

H (m) vs Q (m³/h)
Pump curveSystem curveOperating point

NPSH margin map

Head (m) vs Q (m³/h)
NPSH availableNPSH required1 m design threshold
Operating flow
—m³/h
— L/s
Operating head
Pump / system intersection
NPSH margin
—m
Available − required
Shaft power
—kW
Hydraulic power — kW
Independent check
—m³/h
Bisection vs closed form

How to read the result

The operating flow is where the pump head curve meets the system curve. A positive NPSH margin means the available suction head exceeds the illustrative required head; a design margin of at least 1.0 m is used here as a teaching threshold, not a universal acceptance criterion.

Model status

Textbook pump/system intersection with illustrative suction-loss and NPSHr curves. Water properties vary with temperature; the geometry is scaled for explanation.

The science · equations, assumptions and limits
Hydraulic operating point
Hₚ = H₀ − aQ²
Hₛᵧₛ = Hₛ + kQ²
Equating the curves gives Q* = √[(H₀ − Hₛ)/(a + k)] when H₀ exceeds Hₛ. Q is in m³/h and the curve coefficients carry the corresponding units.
Suction head and cavitation margin
NPSHₐ = (pₐₜₘ − pᵥ)/(ρg) + z − kₛQ²
NPSHᵣ = 2.2 + 0.00125Q²
The vapour pressure uses the Buck water equation. NPSHr is an illustrative manufacturer-style curve; actual values require a tested pump curve and installation data.
Power
Pₕ = ρg(Q/3600)H
Pₛₕₐ𝒻ₜ = Pₕ/η
Density is approximated over the displayed temperature range. The model omits detailed impeller losses, transient pressure pulsations, dissolved gas, local blade pressure fields and cavitation erosion.
Scientific labels
Textbook: steady pump/system curve intersection and Bernoulli-based NPSHa. Illustrative: pump coefficients, suction resistance and NPSHr curve. Scaled: all visual geometry and flow animation. This is an educational steady-state model, not a pump selection or safety tool.
Illustrative design, not affiliated with any real institution or manufacturer.
Made with 🤖 ChatGPT