α = N·s · R = N·r · K = N·k
I = α(Th − Tc) / (R + RL)
Pload = I²RL · Vload = IRL
Qh = KΔT + αThI − ½I²R
Qc = KΔT + αTcI + ½I²R
Efficiency is Pload / Qh. The independent check recomputes load power from the closed-form Thevenin expression.
Constant Seebeck coefficient, electrical resistance and thermal conductance; steady-state operation; equal splitting of Joule heat between the two faces; ideal thermal contacts.
Temperature-dependent properties, Thomson heat, contact resistance, radiation, parasitic heat paths and real module geometry are omitted. The visual leg array is illustrative, while N controls the lumped model.
Labels: textbook = equations; illustrative = schematic; scaled = visual dimensions.
Illustrative design, not affiliated with any real institution or manufacturer.