Vapour deposition
Water vapour deposits when the air-side vapour density exceeds saturation at the sub-zero coil surface:
J = hₘ · max(ρᵥ,air − ρᵥ,ice, 0)
Vapour density is calculated from saturation vapour pressure and the ideal-gas relation, ρᵥ = e/(RᵥT). The mass-transfer coefficient hₘ is illustrative.
Frost and heat transfer
δ = m″ / ρf · Rf = δ / kf
The frost layer adds thermal resistance in series with the clean coil. A separate illustrative obstruction factor reduces airflow as frost accumulates.
Defrost water and refreezing
ṁfreeze = min(ṁwater, Pcool / Lf)
The drain pan follows a lumped thermal response: T(t) = Teq + (T₀ − Teq)e⁻ᵗ/τ. When the pan is below 0 °C, a simplified heat-removal term can freeze some meltwater. Ice reduces the available drain capacity.
What is simplified
- The outdoor coil is represented by one uniform surface temperature and a uniform frost layer.
- Humidity and air pressure are spatially uniform; the coil has no fin-by-fin temperature variation.
- Defrost heat, frost density, conductivity, mass-transfer coefficient, pan thermal mass and drain geometry are illustrative equipment values.
- Pan temperature is a lumped state. Water-film flow, splash, wind, detailed refrigerant dynamics and local ice geometry are not resolved.
- The heating COP uses a fixed illustrative fraction of the Carnot heating limit. It is not a product rating or field prediction.
Constants marked textbook: water's latent heat of fusion is approximately 334 kJ/kg; water-vapour gas constant is approximately 461.5 J/(kg·K); dry-air specific heat is approximately 1005 J/(kg·K). Remaining plant dimensions and coefficients are illustrative.