What you see. A steel silo about 6 m high filled with 120 tonnes of dry sand, wrapped in 0.5 m of mineral wool. Electric rods heat the sand when power is cheap; later, air blown through channels in the sand carries the heat to a district-heating exchanger. The glowing disc at the top is the temperature field of a horizontal slice through the bed.
Heat in the sand. Around each rod the bed is divided into identical unit cells of radius Rc (the area-equivalent circle of the rod pitch). In a cell, heat conduction is ρ c ∂T/∂t = (1/r) ∂/∂r (k r ∂T/∂r) − g (T − Ta) − X (T − Tair,in) δ(r − rp), with the rod power entering at the inner radius and the rod thermostat holding the rod surface at Tmax. It is solved with an implicit finite-volume scheme on 48 geometric cells, which conserves energy exactly. The whole battery is N = R²/Rc² identical cells.
Why spacing matters. The steady spread between rod and cell edge is P'/(2πk(Rc²−rh²)) [Rc² ln(Rc/rh) − (Rc²−rh²)/2]. Sand conducts so poorly (about 0.3 W/m/K) that with rods far apart the rod reaches its limit while the outer sand is still cold, so the heater has to throttle and the battery charges slowly and incompletely.
Loss and discharge. Standing loss uses the silo area and the insulation resistance t/kins + 1/hout, shared out over the sand by heat capacity. Air takes heat at the ring rp with effectiveness ε = 1 − e−NTU; a controller sets the air flow so that the delivered power matches the demand until the ring has cooled too far.
Honest simplifications. Heat flow is purely radial and the same at every height; the real bed also has axial and wall effects. Conductivity, density and specific heat (830 J/kg/K; real sand rises by about a third up to 500 °C) are constants, and the effective conductivity stands in for radiation and air movement in the pores. The loss is spread evenly over the sand instead of being drawn from the outer layer, so a real battery loses a bit less when its core is hot and its rim is cold. Numbers such as NTU, insulation conductivity and spacing are plausible design values, not data of a particular plant. The Finnish sand batteries that inspire the topic are not modelled in detail.
Checks. (1) The energy ledger closes to machine precision including the rod limit and the discharge; (2) the early temperature rise equals the exact line-source solution with the exponential integral; (3) the quasi-steady profile and the warming rate in a closed cell equal their analytic forms; (4) the sand volume integrated from the Blender mesh equals the cylinder formula.