Pelton Turbine: From Water Jet to Electricity
Follow the force of a water jet as it turns a runner and drives a generator.
Numerical checks
Independent calculations at the current illustrative settings. Differences are relative to the reference, with an absolute floor near zero.
The science Equations, assumptions and limitations
Textbook fluid mechanics
v = √(2gH), A = πd²/4, Q = Av, ṁ = ρQ. Jet power Pj = ½ṁv² = ρgQH. Textbook gravity g = 9.81 m/s²; illustrative water density ρ = 1000 kg/m³.
Impulse and rotation
u = Rω, F = ṁ(v − u)(1 − cos β), τ = RF. Here β is the turning angle of relative water velocity. For 0 ≤ u ≤ v, τ = a − cω with a = ṁRv(1 − cos β), c = ṁR²(1 − cos β). Outside this range the jet torque is clipped to nonnegative values.
Generator and energy
I dω/dt = τ − (b + k)ω. Bearing coefficient b = 0.12 N·m·s/rad and generator load k are illustrative. Electrical power = ηkω², with illustrative η = 0.90. The remaining power is water loss, bearing loss, generator heat and signed rotor-energy storage. Steady ω = a/(c + b + k).
Numerical method and limits
Fixed step Δt = 1/240 s; exact exponential relaxation and integrated angle over each step. An overspeed rotor coasts until the jet catches it. The model neglects nozzle loss, bucket friction, splash, partial admission, transient generator fields and cavitation. Geometry, water streaks and time presentation are illustrative; no real machine is represented. Not affiliated with any turbine manufacturer.