Aggregate work ÷ aggregate heat capacity rise versus the mean of individual run estimates.
Joule’s Paddle Wheel
Can falling weights turn mechanical work into a measurable rise in temperature?
The weights descend slowly, turning the shaft. The paddle wheel shears the water against fixed vanes; friction converts the input work into heat.
Four independent checks
The same measurements are checked by separate calculation routes. Each difference is shown against its stated tolerance.
Bootstrap mean from 2,000 resamples versus the closed-form estimate.
Modern water heat capacity prediction versus the measured mechanical input.
Joule’s vacuum-corrected published result versus the 15 °C calorie reference.
PASS thresholds: 1% for calculation agreement, 2% for energy balance, and 1% for the historical comparison. A failed preset is intentionally allowed to fail the physics check.
What Joule actually built
REFERENCE NOTESThe science+
Equations
Mechanical work: W = F × h + Wstring. The paired lead load is multiplied by the corrected total fall; Joule also added a small string-elasticity correction.
Heat absorbed: Q = Ccal × ΔT, where Ccal is the combined water-equivalent heat capacity of the water, copper can, brass wheel and stopper.
Mechanical equivalent: J = W / (Ccal × ΔT). The exhibit converts the result to joules per gram per degree Celsius.
Noise and corrections
Run-to-run thermal residuals are bootstrapped from the forty friction-minus-radiation pairs in Joule’s first water series. Their measured standard deviation is about 0.0101 °F. The original 0.005 °F thermometer readability is represented by two independent uniform reading errors.
Ambient exchange is modelled linearly using Joule’s measured coefficient, 0.04654 °F per °F of room-to-vessel temperature difference over a 35-minute run. The checkbox applies the matched blank-run correction.
The replay assumes a well-mixed calorimeter, constant effective heat capacity, a linear heat-leak response and no evaporation. The visual descent is accelerated; the numerical model uses fixed time steps for the motion.
Reference values
Joule’s water series: 773.640 ft·lbf per lb·°F in air and 772.692 after correction to vacuum. His paper identifies the vacuum-corrected value as his most reliable result.
The modern comparison uses the NIST value for the 15 °C calorie: 4.18580 J. Joule’s result converts to approximately 4.1573 J/g·°C, about 0.68% lower.
This is an educational reconstruction, not an official reproduction or an affiliated exhibit of the Science Museum Group or any historical institution.