REBUILT HISTORICAL EXPERIMENT · MANCHESTER, 1849

Joule’s Paddle Wheel and the Mechanical Equivalent of Heat

CANVAS LAB
THE APPARATUSDrag to inspect · rightward drag moves the apparatus right
LIVE READOUTS

What the apparatus is doing

ILLUSTRATIVE MODEL
Mechanical work per trial8.25 kJ
Expected rise before room drift0.562 °F
Run the experiment to collect noisy thermometer readings. The modern reference is 778.169 ft·lbf/BTU (textbook).
MEASUREMENT VS THEORY

Mechanical equivalent of heat

ft·lbf / BTU

Historical whiskers show published between-series spread; the water whisker is a propagated thermometer-resolution estimate, not a published confidence interval.

INDEPENDENT NUMERICAL CHECKS

Does the reconstruction add up?

Each check is labelled by source or model
HISTORICAL ARITHMETIC773.640 ft·lbf/BTU

Joule’s corrected work divided by measured heat capacity, before the vacuum correction.

0.000% difference from Joule’s table
TEXTBOOK UNIT CHAIN778.169 ft·lbf/BTU

1,055.056 J per IT BTU divided by 1.355818 J per foot-pound force.

0.000% difference from modern reference
MONTE CARLO · MODEL— ft·lbf/BTU

Mean of 6,000 synthetic thermometer pairs using quantisation and Gaussian control residuals.

Calibration check loading
FIELD NOTESThe scienceEquations, assumptions and historical limits +
MECHANICAL WORK

W = 2 m g h N (1 − f) + Wstring

Two falling masses do work over N drops. The baseline pulley-friction fraction f is reconstructed from Joule’s measured 2,837-grain loss out of 406,152 grains; string elasticity is scaled from his reported correction.
HEAT MEASURED

Q = Cwater ΔTcorrected

The calorimeter’s total water-equivalent heat capacity is 97,470.2 grains (6.316 kg). Room drift is subtracted using the stationary control reading before converting Fahrenheit to kelvin.
THE CONSTANT

J = W / (Q / 1,055.056 J) / 1.355818

The result is expressed in foot-pound force per IT British thermal unit. The modern textbook reference is 778.169 ft·lbf/BTU.
NOISE MODEL

ΔTread = round(Tend / r)r − round(Tstart / r)r + ε

Each thermometer reading is quantised to step r. The control residual ε is Gaussian with σ = 0.0081 °F per twenty-fall trial, estimated from the 40 stationary-control observations in Joule’s Table I after subtracting his measured 0.04654 °F-per-°F ambient response. This reconstructed distribution is an approximation, not a formal confidence interval reported by Joule.

Historical uncertainty: Joule did not publish a formal confidence interval for the 772.692 water result. The chart therefore shows a one-paired-reading uncertainty propagated from his stated 0.005 °F readable increment, and shows the mercury and cast-iron ranges as the spread of their two published series. These are not statistical confidence intervals.

Simplifications: the calorimeter is treated as one lumped heat capacity; water heat capacity is fixed at the IT-calorie value; the actual room drift is held at the published mean; and the animation’s rotor drag is illustrative. The scene is scaled and the falling weights are visually accelerated. The measured constant is calculated from the energy and thermometer model, not from the animation speed.

Educational reconstruction only. Not affiliated with James Prescott Joule, the Royal Society, or any museum or historical institution.

Made with 🤖 ChatGPT