POWER SYSTEMS / FIELD STUDY

How One Shaded Section Rewrites a Solar Panel's Output

A solar module is a series circuit wearing a glass face. Shade one section and the whole string must negotiate a new current path. Watch the bypass diodes change the shape of the power curve.

LIVE APPARATUS

Series-connected solar module

LIVE MODEL
↔ DRAG TO PAN SCHEMATIC / NOT TO SCALE
WHAT YOU ARE SEEING

All four sections receive the same sunlight. Their bypass diodes are idle, so the module behaves like one long series string.

OUTPUT SIGNATURE

Current and power curves

MODULE RESPONSE MAXIMUM POWER
Illustrative single-diode model · current sweep from 0 AGLOBAL PEAK FOUND
MEASUREMENT EXPERIMENT

Find the maximum power point

Scan the string current, measure voltage at each step, and compare the largest measured power with the model's refined prediction.

Ready · 240 current samples

MODEL NOTESThe science+

1 · The single-diode cell-group model

Each of the four series substrings is represented by 18 cells in one lumped model. Its current is the photocurrent minus diode and shunt currents:

IPV = Iph − I0[exp(V/a) − 1] − V/Rsh

Here a = nNskT/q. The reference substring values are 9.2 A short-circuit current and 10.8 V open-circuit voltage at 1,000 W/m² and 25 °C. The model uses an illustrative 250 Ω shunt resistance and an empirical temperature coefficient.

2 · Bypass diode and series connection

A bypass diode is connected antiparallel across each substring. When the substring is driven below zero volts, its forward current is approximated by a Shockley diode equation. A failed path uses a simple −18 V reverse-bias clamp with 0.12 Ω slope resistance; this is a numerical stress indicator, not a thermal or damage prediction.

I = IPV(V) + Ibypass(V) + Ireverse(V)

The same string current passes through all four sections. Their voltages add: Vstring = ΣVj, and electrical power is P = IV. A bisection solver finds each section voltage for a requested current; a coarse global scan followed by a local golden-section search locates the maximum-power point.

3 · What is simplified

The module is an illustrative four-substring device, not a specification for a particular product. Cell mismatch inside each substring is averaged into one photocurrent. The 8% diffuse-light floor, diode saturation current, reverse-bias clamp, and electrical parameters are illustrative. Wiring resistance, bypass-diode heating, cell temperature gradients, optical reflection, ageing, and dynamic inverter behaviour are not modelled.

4 · Reading the result honestly

Partial shade can create more than one local maximum on the power curve. A controller that searches only near its previous operating point may settle on a lower peak. This model shows the electrical mechanism and compares a current sweep with the computed global maximum; it does not predict a real installation's yield, safety, or lifetime. All live values are model outputs, not measured field data.

FIELD GUIDE / PHOTOVOLTAIC ELECTRICS

Why a small shadow can change the whole circuit

A solar module looks like a flat collection of blue cells, but electrically it behaves more like a chain. The same current must pass through each series-connected section. When one section receives much less light, its ability to supply current falls — and the rest of the module cannot simply ignore that bottleneck.

Series current is shared

In a series circuit, the current is common to every element while the voltages add. Photovoltaic cells generate current when photons create mobile charge carriers. More incident light generally produces more photocurrent. A shaded cell group therefore has a lower current capability than its illuminated neighbours.

If the string current is kept low enough for the shaded section, the other sections are also forced to operate at that lower current. If the string current rises, the shaded section may be driven into reverse voltage. It is this conflict — not simply a dark patch absorbing sunlight — that reshapes the module's electrical output.

The diode creates another route

Many modules divide their cells into substrings, each protected by a bypass diode connected in the opposite direction across that group. Under ordinary illumination the substring produces a positive voltage and the bypass diode remains off. When the substring is forced negative, the diode can conduct and provide a path around the group.

That path costs voltage. The shaded substring is no longer contributing its normal positive voltage to the series total; instead, the conducting diode contributes a small negative drop. The remaining illuminated substrings can continue to deliver current. Bypass diodes therefore trade some voltage for a way to keep the rest of the string operating.

Why the curve can have several peaks

With uniform illumination, the current–voltage curve has the familiar smooth photovoltaic shape. The power curve rises, reaches one broad maximum, and then falls as voltage approaches open circuit. Under partial shade, different substrings can enter bypass at different currents. Each change in conduction alters the total string voltage.

The resulting power curve can contain multiple local maxima. One may occur at a lower current with every substring contributing voltage; another may occur at a higher current after a shaded substring has been bypassed. The global maximum is the highest of these peaks, not necessarily the first peak encountered during a search.

What the model calculates

This observatory uses a single-diode approximation for each substring. Photocurrent scales with irradiance, while a diode term and a shunt-leakage term describe the fall in current as terminal voltage rises. For a requested string current, a bisection solver finds the voltage of each substring. Their voltages are added to obtain the module voltage, and multiplying by current gives power.

The bypass path is represented by a diode equation. If its condition is set to zero, the model instead uses a simple reverse-bias clamp. This makes the electrical consequence of a failed bypass path visible without pretending to calculate the temperature of an individual cell or the likelihood of physical damage.

Temperature and sunlight matter too

Higher irradiance increases photocurrent, so a bright unshaded module can generally deliver more current and power. Temperature has a different influence: for silicon photovoltaic devices, higher cell temperature usually reduces voltage. The observatory applies an illustrative voltage coefficient and a smaller positive photocurrent coefficient to make this contrast visible.

Real modules also respond to spectrum, angle of incidence, cell mismatch, wiring resistance, and local temperature. Their published electrical parameters are measured under defined test conditions. The values here are representative teaching parameters, not a product datasheet or a prediction for a rooftop array.

Why a current sweep is useful

A maximum-power-point tracker changes the operating point of a photovoltaic array so that voltage and current produce as much power as possible. In a uniformly illuminated string, the power curve is comparatively simple. Partial shade can create several candidate peaks, so a local search may miss the global one if it does not explore enough of the curve.

The experiment in this page steps the current through a range, calculates the corresponding voltage, and records the largest sampled power. It then compares that measurement with the refined model estimate. The difference is a numerical resolution check: a finite sweep can approach the true model peak, but it samples only discrete current values.

Model boundary: The visualisation explains the electrical behaviour of a simplified four-substring module. It does not model thermal runaway, fire, installation design, inverter control, or the safety of real equipment. All parameters and outputs are illustrative.
QUESTIONS FROM THE FIELD

Eight useful questions

Why can one shaded cell affect cells that are still in sunlight?

Series-connected cells share the same current. A shaded cell group cannot independently choose a lower current while the other groups continue at a higher one. The string operating point is a compromise set by the electrical characteristics of every section.

Does a bypass diode make shading harmless?

No. A conducting bypass diode can prevent a shaded substring from blocking the current of the rest of the string, but the bypassed section no longer contributes its normal voltage. The module still loses power, and real behaviour depends on cell layout, diode design, and the pattern of shade.

Why are bypass diodes normally switched off?

When a substring is generating a positive terminal voltage, the antiparallel bypass diode is reverse-biased. It begins to conduct when the substring voltage becomes sufficiently negative, providing an alternate path for the series current.

What causes multiple peaks on the power curve?

Different substrings can become bypassed at different current levels. Each transition changes the sum of substring voltages, so the product of current and voltage can rise and fall more than once before reaching its global maximum.

Is the shadow coverage slider the same as shading one cell?

No. It represents an averaged reduction in irradiance for a selected substring or pair. Real cell-level shade can produce stronger mismatch within a substring. The averaged model is designed to show the series and bypass mechanism without resolving every individual cell.

Why does higher temperature usually reduce module voltage?

Higher temperature changes the semiconductor diode current and reduces the open-circuit voltage of silicon cells. Photocurrent rises slightly with temperature, but that small increase usually does not offset the voltage reduction. The temperature coefficients here are illustrative.

What does the failed-diode preset show?

It removes the bypass diode's forward-current path. A shaded section can then be driven into the model's reverse-bias clamp, reducing string output. The clamp is an illustrative electrical boundary only; it does not calculate hot-spot temperature, damage, or a safe operating limit.

Why can the measured sweep differ from the predicted maximum?

The sweep checks only a finite set of current values. Its best sample may fall slightly to either side of the refined maximum. Increasing the number of samples would usually reduce this discretisation difference, while measurement noise and control delays would add further differences in a real system.