Explore how a vertical borehole heat exchanger interacts with surrounding ground. Change geological properties, design loads, borehole resistance and operating schedules. Every laboratory uses the same transient radial finite-volume model, so a saved scenario can be carried from one experiment to another.
Inspect the U-tube, grout, borehole wall and radial ground-temperature field.
Open laboratory → LAB 02 / RESPONSETrack wall and mean-fluid temperatures as the ground responds to a heat load.
Open laboratory → LAB 03 / EXPERIMENTRun extraction, idle and injection phases with a user-defined load schedule.
Open laboratory → LAB 04 / COMPARISONCompare conductive ground, thermal capacity and borehole resistance scenarios.
Open laboratory → LAB 05 / MATHEMATICSExplore diffusivity, diffusion length, cylindrical resistance and grid convergence.
Open laboratory → LAB 06 / CHALLENGEFind the maximum extraction load that keeps fluid temperature above a limit.
Open laboratory → LAB 07 / DATAFit conductivity and borehole resistance to a synthetic field-response dataset.
Open laboratory → LAB 08 / SEASONALStudy how rest periods and heat injection restore the ground after extraction.
Open laboratory →The ground is represented as homogeneous cylindrical soil around a long vertical borehole. A prescribed line load is applied at the borehole wall; the far-field boundary is held at the undisturbed ground temperature.
Positive q′ means heat is extracted from the ground into the fluid. Negative q′ means heat is injected into the ground. Fluid temperature is the modelled mean loop-fluid temperature, not a separately resolved inlet/outlet pair.