Induction heating: coil, skin effect and the Curie plateau

Blender-built workstation with a see-through bar showing eddy-current density and an end-face temperature map, driven by the complex skin-effect and heat-conduction solver of the 2D page.

Switch to 2D

Presets

Playback

Material, coil and run

Camera

Layers

Quality

Model check

The science

What you are looking at

A bar of steel, aluminium or copper lies on ceramic V-blocks inside a water-cooled copper coil, fed from an induction power supply (all Blender 5.2 models; the coil helix is generated from your number of turns). Its end face shows the temperature across the bar as a colour map, the bar surface glows with its own temperature, and the dots in the see-through bar are the eddy currents: their number per ring follows the computed current density, so at higher frequency they crowd into the skin. The blue loops are the alternating magnetic field, drawn pulsing at a slowed-down rate.

Model

In a long solenoid the axial field H(r) in the bar obeys (1/r) d/dr (r ρ dH/dr) = jωμ H with H(a) = N I/ℓ. The eddy-current density is J = −dH/dr, the heating source q = ρ|J|²/2, and for a ≫ δ the current flows in a layer about δ = √(ρ/(π f μ)) thick. Resistivity rises with temperature, and above the Curie point (770 °C) carbon steel loses its magnetic permeability, so its skin depth jumps and the surface heating stalls while the core catches up. Heat then diffuses inward by conduction, ρc ∂T/∂t = (1/r) ∂/∂r (r k ∂T/∂r) + q, with convection and radiation at the surface. The coil is a 6 mm copper tube whose own skin depth sets its loss.

Honest simplifications

Long coil with a uniform field (no end effects), constant relative permeability below the Curie point (real steel saturates), no phase-change heat, lumped cooling coefficient, bar ends shown protruding 20 mm only for display. The eddy-current dots and field loops are illustrative: counts are proportional to the solved current density, but the animation rate is slowed far below the real kilohertz.

Checks run in the page

  • The six numerical checks of the 2D page: skin depth in the solved field, thin-bar and thick-bar limits, Joule heat equals Poynting flux, adiabatic enthalpy ledger, conduction eigenmode.
  • The coil helix measured in the scene: its wire length must match the helix formula and the length used for the coil loss, and its radius must equal bar radius plus the 8 mm gap.
  • The end-face temperature texture is read back from rendered pixels and inverted through the colour scale; core and surface must match the model within 30 K.

Credits

Blender 5.2 workstation (cabinet, bar blocks, rail, bench) with Cycles-baked metal and brick textures (Draco GLB); Three.js r160.