The science
What this models
An off-grid power system for a small apiary: a PV array charges a battery through an MPPT controller; an inverter feeds the honey-house loads, the electric fence and the hive monitors. Every hour of the run is stepped: solar geometry, irradiance on the tilted plane, cell temperature, array output, battery state of charge, and any load that cannot be served.
Solar geometry and irradiance
Declination d = 23.45 sin(360 (284+n)/365), sunset hour angle cos ws = -tan(phi) tan(d). Extra-terrestrial energy on a horizontal plane: H0 = (24/pi) Gsc E0 (cos phi cos d sin ws + ws sin phi sin d). Daily global H = Kt H0 (Kt is the clearness index). The hourly split uses Collares-Pereira and Rabl; the diffuse share comes from the Erbs correlation; the tilted plane uses the Liu-Jordan isotropic-sky model: I_T = I_b R_b + I_d (1+cos b)/2 + I rho (1-cos b)/2, with R_b = cos(theta)/cos(theta_z).
Array and battery
Array power P = Wp (I_T / 1 kW/m2) [1 - 0.004 (Tcell - 25)] PR eta_MPPT (1 - soiling) with Tcell = Tair + (NOCT-20)/800 I_T (NOCT 45 C). Battery: usable energy C x DoD; charge and discharge each lose sqrt(eta_roundtrip); the controller disconnects the load at the DoD floor. Autonomy of a full battery with no sun: days = C DoD sqrt(eta) / (L/eta_inv). Rules of thumb shown in the readouts: panel size Wp = L / (PSH PR) for a mean-day balance and battery size C = L N_aut / (DoD sqrt(eta)).
Weather
Daily clearness index follows a clipped AR(1) series around the mean Kt: persistence makes dull days cluster, which is what empties real batteries. The seed button draws a new sequence. This is a statistical stand-in, not a measured weather record.
Honest simplifications
- Isotropic sky (underestimates circumsolar and horizon-brightening diffuse); fixed equator-facing array; no snow, no partial shading beyond the dirt/shading slider; no inverter standby loss; battery has no temperature, rate or ageing effects (a real lead-acid bank loses life when cycled deeply, which is why the default DoD is 50 %).
- Load windows are fixed times of day; real use varies. Ambient temperature is a sine around the mean you set.
- For a real installation, use measured irradiation (for example PVGIS) and manufacturer data, and have a qualified electrician certify the wiring.
Checks run in the page
(1) The closed-form H0 against a numerical integral of the sun's cosine over the day, and the hourly split against Kt H0. (2) Battery autonomy: simulated delivered energy and cut-off hour against the closed form. (3) Energy balance of the battery over the whole run.
What to try
- Choose UK December: low sun, then Flat panel: tilt matters most when the sun is low. Press Set best tilt and watch the yield curve and the unmet load.
- Choose Dull spell, small battery. Raise the spell persistence and see the charge fall to the red cut-off line; then double the battery in the design chart (graph 4) versus adding panels.
- Press Size panels for 99 % and compare the result with the rule-of-thumb readout "Wp for mean-day balance".
- Turn the fence and monitors off and see how much of the daily load they are (about 240 Wh) compared with one hour of the extractor.