Parabolic Trough Solar Plant

A traced-ray end view of one collector plus a schematic of the field, molten-salt tanks and power block. Same sun, loop and dispatch model as the 3D plant.

Switch to 3D
Scenario presets

Switches and actions
Alarms
    Numerical checks
    The science

    From sunlight to a hot oil loop

    A parabolic trough focuses direct normal irradiance (DNI) onto an absorber tube at the focal line, z = x2/(4f), with f = 1.71 m and a 5.77 m aperture. The troughs lie north-south and rotate east-west to follow the sun. The sun's incidence angle on the aperture is cosθ = √(cos2θz + cos2δ sin2ω) (declination δ, hour angle ω), and at solar noon this reduces to cos(φ - δ), which the numerical checks verify. Clear-sky DNI uses a Meinel/Hottel-type atmosphere with airmass, I = 1.353 e0 [(1 - 0.14 h) 0.7AM0.678 + 0.14 h] and is reduced by haze, clouds and mirror cleanliness.

    Optical and thermal efficiency

    Optical efficiency is η0 K(θ) with the incidence-angle modifier K = cosθ + 0.000884 θ/cosθ - 5.369e-5 θ2/cosθ (LS-2 type collector, θ in degrees), an end-loss factor 1 - f tanθ/L and low-sun shading. The receiver loses heat as q = 0.141 ΔT + 6.48e-9 ΔT4 W per metre (Dudley et al., LS-2), which is why hotter outlet temperatures cost efficiency. Along a 600 m loop the oil follows dT/dx = (qabs - qloss(T)) / (m cp(T)) with cp = 1.498 + 0.002414 T kJ/kg/K (synthetic-oil type). The controller sets the flow per loop (3 to 12 kg/s) to hold the outlet at the setpoint; if even the minimum flow overheats the oil, mirrors are defocused. Above 15 m/s wind the collectors stow face-down.

    Molten-salt storage and dispatch

    Surplus heat charges a two-tank system: salt at 292 C is heated to 386 C and held in the hot tank. The energy per kilogram is cp (386 - 292) = 143 kJ/kg with cp = 1.443 + 0.000172 T, so a 7.5-hour 50 MWe store holds about 19 000 tonnes. Three dispatch strategies are offered: solar-first (run whenever heat exists, store surplus), evening peak (store by day, full power 17-24 h) and constant output. The 50 MWe steam block has efficiency 0.385 (0.82 + 0.18 L) and a minimum load of 25 %, derated slightly for hot air. Parasitics (pumps, trace heating, fans) are subtracted to give net power.

    Honest simplifications

    Each of the 14 rows in the 3D view stands for a group of loops and is drawn shorter than a real 600 m loop. One lumped loop is solved and scaled by the loop count; the oil thermal inertia is a 150 s lag; tank temperatures are constant; heat-exchanger approach temperatures, start-up and warm-up energy, freeze protection, row-to-row shading and the circumsolar radiation are ignored; the block efficiency is a simple load curve. Clear-sky DNI is smooth, clouds are only a slider and an optional 20-minute event. The model resembles a 50 MWe Andasol-type plant for teaching and is not based on any plant's measured data.